LiteMat Plus is the must-have Luminaire for Hybrid/White Light. Efficient and full-spectrum, LiteMat Plus is constructed with our state-of-the-art CineMitter chips. CineMitters offer a widely extended Kelvin range, along with high 95+ CRI Output. This allows users create anything from a candlelight/deep-tungsten look to an overcast sky/cool white fluorescent look. LiteMat Plus sets the standard for cinematic lighting..

FAQs

LiteMat Plus:

  • LiteDimmer Plus DC 100G
  • LiteDimmer Plus DC 100V
  • LiteDimmer Plus DC 200G
  • LiteDimmer Plus DC 200V
  • LiteDimmer Plus DC 200 Duo
  • LiteDimmer Plus AC 400 Duo

Yes, they are! That’s one of the great features of the LiteMat product line.

Quick Access

Troubleshooting your LiteMat Plus

LiteMat Plus:

Perform a Factory Reset on the LiteDimmer Plus DC 200 or the LiteDimmer Plus AC 400.

1. Set the main 3-position switch to the MENU (center position).

2. Push center button under “INFO”.

3. Push left button under “RESET”.

4. When screen indicates “Cycle Power Now”, disconnect the AC or DC

power source.

5. When screen goes dark, wait 5 seconds.

6. Reconnect the AC or DC power source to unit.

7. Your dimmer has been reset and returned to factory default settings.

Unless the Dimmer has been Factory Reset, the device will return to

the previously selected settings. In LOCAL MODE, Light Intensity and Light

Color are controlled via the LEVEL and KELVIN knobs respectively.

Perform a Factory Reset on the LiteDimmer Plus DC 100G/100V or the LiteDimmer Plus DC 200G/200V.

1) Provide DC power to either battery plate(s) or the alternate PL4 DC voltage

input. See “POWERING THE DC100 & DC200” above, observing voltage

requirements.

2) Place the switch in the center (OFF) position.

3) Press and hold the PROG button for approximately 8 seconds until

the indicator light flashes red very rapidly.

4) Release the PROG button. At this point, the software version will flash

on repeat.

5) Disconnect the DC power source.

6) Reconnect the DC power source.

Your preferences and settings may now have to be reset.

If the DC100 or DC200 is still experiencing irregular operation after a

factory reset, contact LiteGear Technical Support for assistance.